Passenger Elevators Space Required For Manual Door (collapsible Gate/swing Door)
|
Car Inside |
Life Well |
Machine Room |
Speed |
PIT |
Over Head |
|||
|
Persons |
Rated Load |
INTERIOR |
I-UNIT INSTALLATION |
ENTRANCE WIDTH |
I-UNIT INSTALLATION |
|||
|
KG |
Wide CW x Depth CD |
Wide HW x Depth HD |
CO (mm) |
Wide MW x Depth MD |
||||
|
5 |
340 |
1170x820 |
1600x1200 |
760 |
2515x4000 |
Up To 1.5 |
1600 |
4800 |
|
6 |
408 |
1100x1000 |
1600x1400 |
760 |
2515x4000 |
1600 |
4800 |
|
|
8 |
544 |
1300x1100 |
1800x1500 |
760 |
2715x4000 |
1600 |
4800 |
Passenger Elevators Space Required For Centre - Opening Doors (Auto Door)
|
Car Inside |
Life Well |
Machine Room |
Over Head |
|||||
|
Persons |
Rated Load |
INTERIOR |
I-UNIT INSTALLATION |
ENTRANCE WIDTH |
I-UNIT INSTALLATION |
|||
|
KG |
Wide CW x Depth CD |
Wide HW x Depth HD |
CO (mm) |
Wide MW x Depth MD |
||||
|
6 |
408 |
1290x910 |
1600x1525 |
700 |
1600x3500 |
0.7 Upto 1.5 |
4400 |
|
|
8 |
544 |
1300x1100 |
1900x1800 |
800 |
3400x4400 |
4400 |
||
|
10 |
680 |
1350x1300 |
1900x2050 |
800 |
3300x4500 |
5100 |
||
|
13 |
884 |
2000x1100 |
2500x1900 |
800 |
4000x4400 |
4500 |
||
|
2000x1100 |
2500x1900 |
900 |
5100 |
|||||
|
16 |
1088 |
2000x1300 |
2500x2100 |
1000 |
4000x4600 |
1 |
4800 |
|
|
20 |
1360 |
2000x1550 |
2500x2400 |
1000 |
4000x4900 |
1 |
1800 |
4800 |
Hospital Elevators Space Required For Manual Door (collapsible Gate Acodion Type/Auto Door)
|
Car Inside |
Life Well |
|
Machine Room |
Speed |
PIT |
Over Head |
||
|
Persons |
Rated Load |
INTERIOR |
I-UNIT INSTALLATION |
ENTRANCE WIDTH |
I-UNIT INSTALLATION |
|||
|
|
KG |
Wide CW x Depth CD |
Wide HW x Depth HD |
CO (mm) |
Wide MW x Depth MD |
|
|
|
|
15 |
1020 |
1000x2400 |
1800x3000 |
900 |
3700x5500 |
Up To 1.5 |
1700 |
4400 |
|
20 |
1360 |
1300x2400 |
2200x3000 |
1200 |
4200x5500 |
1700 |
4400 |
|
|
26 |
1768 |
1600x2400 |
2350x3000 |
1200 |
4350x5500 |
1700 |
4400 |
Freight Elevators Space Required For Manual Door (collapsible Gate)
|
|
|
Car Inside |
Life Well |
|
Machine Room |
Speed |
PIT |
Over Head |
|
Persons |
Rated Load |
INTERIOR |
I-UNIT INSTALLATION |
ENTRANCE WIDTH |
I-UNIT INSTALLATION |
|||
|
|
KG |
Wide CW x Depth CD |
Wide HW x Depth HD |
CO (mm) |
Wide MW x Depth MD |
|
|
|
|
|
500 |
1100x1200 |
1900x1600 |
1000 |
2500x4100 |
Up To 1.5 |
1600 |
4400 |
|
|
1000 |
1400x1800 |
2300x2200 |
1300 |
2500x4700 |
0.5 |
1600 |
4400 |
|
|
1500 |
1700x2000 |
2600x2900 |
1600 |
2600x4900 |
0.55 |
1600 |
5100 |
|
|
2000 |
1700x2500 |
2900x2900 |
1600 |
2600x5400 |
0.55 |
1600 |
4500 |
|
|
2500 |
2000x2500 |
2900x2900 |
1800 |
2900x5400 |
0.4 |
1600 |
5100 |
|
|
3000 |
2000x3000 |
2900x3400 |
1800 |
2900x5900 |
0.4 |
1600 |
4800 |
NOTE:
- for 2 Speed Auto Doors, Hoistway Depth 125 Mm More Required.
- Maximum Opening For 2 Speed Door Will Be 1200mm.
- Vertical Uplifting Car Door & Vertical Bi Parting Landing Doors Are Available As Option Subjects To Availability Of Minimum Floor To Height As (1.5h + 400mm). [h = Opening Height]
Dumb Waiters (space Required)
|
Load |
Speed |
Car Inside |
Machine Room |
ENTRANCE |
|
KG |
m.p.s. |
Wide CW x Depth CD |
Wide HW x Depth HD |
CO X HH |
|
100 |
0.5 |
700x700x800 |
1200x900 |
2500x4100 |
|
150 |
0.5 |
800x800x900 |
1300x1000 |
2500x4700 |
|
200 |
0.25 |
900x900x1000 |
1400x1100 |
2600x4900 |
|
250 |
0.25 |
1000x1000x1200 |
1500x1200 |
2600x5400 |
ABBREVIATION:
- HH : Car & Entrance Height
- RC : Running Clearance
- PD : Pit Depth
- OH : Overhead
- HB : Car Frame Height
- TC : Top Clearance
GENERAL NOTES :
- This Is General Data. We Will Assist You In The Preparation Of Working Drawings.
- All The Dimensions Given In The Table Are In Millimeters.
- The Dimensions In All The Table Meet IS : 3534 Requirement.
- All Hoist Way Wall Should Be Minimum 230 Bricks Or 150 RCC.
- Kindly Seek All Classification From Our Sales Personnel Prior To Finalization.
- The Capacity In Person Is Calculated At 68 K. G. / Person.
- For 0.7/1 M.P.S. Speed Standard Car Height 2300mm & Entrance Height 2000mm.
- for 1 M.P.S. Above Speed Standard Car Height 2400mm & Entrance Height 2100mm.
- Noble Elevators Reserves The Right To Change Any Part Of These Specifications Without Prior Notice.
- IMPORTANT : Centre Opening Doors Are Recommended.
- Dimensions Of The Machine-room Depend On Orientation And Number Of Hoistway In The Building.